Dissolve urea with stirring (it gets cold) can warm to ~ 30ºC. NO
FURTHER
De-gas solution under vacuum
ADD 10 ul TEMED
700 ul 10% ammonium persulphate (make fresh)
Pour gel immediately it cross links in about 10 minutes
Can be used after 45 minutes
Pre-run 15 minutes
Run at 60 watts constant power
Denaturing Double Stranded Templates
2 ug DNA /2 ul
H2O 16 ul
4 M NaOH 1 ul (.2 M final)
4 mM EDTA 1 ul (.2 mM final)
Leave at room temperature 5 min.
2 M NH4OAc 2 ul (1/10th vol)
100% EtOH 55 ul (2.5 vol)
Centrifuge 5 min, remove sup and resuspend in 7 ul H2O
PREPARING THE SEQUENCING GEL
Clean the glass plates with Kimwipes, first with diluted Liqinox, then with distilled
water, then with ethanol until they are squeaky clean. (This is extremely important if
you want to avoid air bubbles when pouring the gel.)
Spray a very small amount of Pam on one side of the larger plate and rub in very
well with Kimwipes.
Assemble the plates with spacers on levelling plate on top of an empty blue tip box.
Clamp with bulldog clamps, one on each side.
Pour the gel using a 60cc syringe to dispense the acrylamide; allowing it to run
between the plates by capillary action.
When the plates are filled with acrylamide, insert the comb upside down, approx.
1cm deep. Clamp the comb and the sides of the gel with bulldog clamps, but do not
clamp the bottom unless you use a bottom spacer. Place plastic wrap around the
bottom of the gel to prevent it from drying out.
Pre-run the gel at 60W for 15-60 minutes or until the gel plates are quite hot to
touch. Make sure that the voltage and current are not limiting by turnig them up all the
way.
Note: ACRYLAMIDE IS A NEUROTOXIN. WEAR GLOVES AND LAB COAT WHEN
HANDLING. READ THE MSDS BEFORE USING THIS CHEMICAL.
A SIMPLE AND RAPID PROCEDURE FOR POURING SEQUENCING GELS
(BioFeedback)
The method is based on the physical phenomenom of surface tension and its
corollary, capillary action. Because of capillary action, gravitaional force is not needed
to draw the fluid into the gel assembly, so it can lie flat. Moreover, if the assembly lies
flat, it is not neccesary to seal the edges for surface tension will prevent the solution
from flowing out. The problem of air bubbles is almost non-existent.
Sequencing plates are detergent-cleaned, rinsed with distilled water and dried
with ethanol. The glass surfaces that will be in contact with the gel are coated with
Pam. The plates are carefully apposed with the side spacers in place. One clamp is
used at the middle of each side. The assembly is placed on a flat level surface.
Raising the assembly above the bench top (we use blue pipette tip boxes) makes it
easier to fill. Gel solution at room temp. Containing 40ul N,N,N',N' -
tetramethyethylenediamine (TEMED) and 500ul 10% ammonia persulfate per 100mL of
solution is released slowly form 25 mL pipet into the middle of the well at what will be
on top of the assembly. The solution is pulled into the space between the plates and
fills it completely. Finally, the comb is inserted and the assembly fully clamped. It is
particularly important to clamp the comb in place. Allow the filled and clamped
assembly to remain in place until the gel has polymerized.
TIPS:
when leaving the gel overnight: wrap bottom with saran wrap to prevent drying
of gel.
do not clamp bottom unless using bottom spacers.
References:
Maniatis, T., E.F. Fritsch and J. Sambrook.
1982. Molecular Cloning: A Laboratory Manual.
Cold Spring Harbour Press, Cold Spring Harbour, N.Y.
Taken from:
Yenhui Chang and Gillian E. Wu
Biotechniques
Vol. 12, No. 1 (1992)